Seitenansicht 17
15
7&8 are the pairs designated by T568A/B for
a RJ45 jack or plug. A cable can be wired
with correct continuity but not with correct
pairing. This most often happens when
the cable is terminated consistently at both
ends, but in the wrong order. A dynamic
or AC test is required to detect this type of
error. If the only error is a split pair error, the
cable has correct continuity. If cross talk
is not a concern, as in flat satin cable, the
cable is good if the only error is the split pair
error. The Split icon and the pin numbers
on the first and second line of the wire map
with split pairs flash when there is a split pair
error.
Resi-Tester™ has the ability to turn off the
split pair error testing. Pressing the button
for the current cable test mode for more than
2 seconds turns off the split pair testing. The
“Split” icon and the word “OFF” appears on
the screen briefly to indicate this. The split
pair testing will resume the next time the
tester is turned on, or may be toggled back
on by another 2 second press of the current
test mode button.