15
with correct continuity but not with correct
pairing. This most often happens when
the cable is terminated consistently at both
ends, but in the wrong order. A dynamic
or AC test is required to detect this type of
error. If the only error is a split pair error,
the cable has correct continuity. If cross
talk is not a concern, as in flat satin
cable, the cable is good if the only error
is the split pair error. The Split icon and
the pin numbers on the first and second line
of the wire map with split pairs flash when
there is a split pair error.
Testifier™ has the ability to turn off the split
pair error testing. Pressing the button for
the current cable test mode for more than 2
seconds turns off the split pair testing. The
“Split” icon and the word “OFF” appears on
the screen briefly to indicate this. The split
pair testing will resume the next time the
tester is turned on, or may be toggled back
on by another 2 second press of the current
test mode button.